Heparin responsiveness before CPB depends partly on how an inadequate response is defined. In a retrospective study of 638 adults, 27.6% had an activated clotting time (ACT) below 450 seconds three minutes after an initial heparin dose of 300 IU/kg. Applying alternative definitions to the same records produced proportions from 14.1% to 43.6%. Routine preoperative laboratory values did not reliably identify which patients would fall below the initial ACT target.
Study Design and Anticoagulation Protocol
Aytünür and Ata examined records from a tertiary cardiac surgical center in Türkiye. The analysis covered operations performed in 2023–2024 and included predominantly coronary surgery: 68.8% were isolated coronary artery bypass procedures. Median age was 61 years, 80.9% were men, and 86.4% had received unfractionated or low-molecular-weight heparin before surgery.
The institutional protocol specified 300 IU/kg of unfractionated heparin through central venous access. Arterial whole-blood ACT was measured three minutes later using an Actalyke MINI II analyzer with MAX-ACT tubes. Local thresholds were at least 400 seconds for cannulation and at least 450 seconds for starting CPB; these describe the study center’s practice rather than a universal target.
The sample was non-consecutive. Investigators stopped reviewing archived record batches after exceeding their minimum sample size, leaving 638 unique patient-operation records from 2,127 CPB operations. The other 1,489 operations were not individually screened. Consequently, the reported proportions describe the selected cohort and cannot be treated as the incidence across all operations at the institution.
One Cohort, Five Different Frequencies
| Definition | Patients | Proportion |
|---|---|---|
| Initial ACT below 450 seconds: primary outcome | 176 | 27.6% |
| Initial ACT below 400 seconds | 90 | 14.1% |
| Initial ACT below 480 seconds | 278 | 43.6% |
| Any additional heparin recorded during the peri-CPB course | 216 | 33.9% |
| Total recorded heparin dose of at least 400 IU/kg | 148 | 23.2% |
The primary estimate had a 95% confidence interval of 24.3%–31.2%. Thirty-six patients had an ACT of exactly 450 seconds; including them by changing the definition from below 450 to 450 or less raised the proportion to 33.2%. This illustrates why the exact inequality, sampling time, assay, and administered dose matter when comparing reports.
An ACT below 480 seconds after 300 IU/kg should not be equated with failure to achieve that target after a larger cumulative dose. The authors could not apply a proposed standardized definition requiring 500 IU/kg. An inadequate response to an initial dose and persistent resistance after escalation describe different clinical situations.
Routine Laboratory Values Did Not Predict the Initial Response
The prespecified 12-variable prediction model was not statistically significant overall (likelihood-ratio P = .135). Its apparent area under the receiver operating characteristic curve was 0.604, falling to 0.550 after bootstrap correction for optimism. An AUC near 0.5 offers little ability to distinguish patients who will have the outcome from those who will not.
C-reactive protein had a nominally significant coefficient within that model: adjusted odds ratio 1.06 per 5 mg/L increase, with a 95% confidence interval of 1.01–1.12. This isolated association is hypothesis-generating; it does not establish CRP as a useful screening test. CRP alone had an AUC of only 0.557.
Blood count-derived inflammatory indices performed similarly poorly. AUC values were 0.529 for the neutrophil-to-lymphocyte ratio, 0.510 for the platelet-to-lymphocyte ratio, and 0.531 for the systemic immune-inflammation index. The study does not support using these markers to select patients for a higher starting heparin dose.
At the alternative 400-second threshold, a model reached statistical significance and fibrinogen showed an association, but optimism-corrected discrimination remained poor at 0.596. These exploratory findings do not supply a validated prediction rule.
What the Records Could and Could Not Show
Additional heparin was recorded in 175 of the 176 patients below the primary ACT target. It was also recorded in 41 patients whose initial ACT was at least 450 seconds. Because dose timing was unavailable, the investigators could not distinguish pre-bypass rescue dosing from maintenance dosing during CPB. A definition based on any additional heparin therefore incorporates treatment decisions and procedure duration as well as initial responsiveness.
Exploratory comparisons found no robust differences in postoperative outcomes between initial-response groups. These outcomes were recorded in broad, non-adjudicated categories, and the study was not designed to establish clinical equivalence or the safety of a particular ACT threshold. A lack of clear outcome differences should not be read as evidence that inadequate anticoagulation is harmless.
Relevance for Perfusion Practice
The useful lesson for perfusion teams is the need to describe and measure the response directly. A report of “heparin resistance” is difficult to interpret without the dose, route, interval to sampling, ACT platform, target, and redosing history. In this cohort, routine laboratory markers could not replace the post-dose ACT measurement.
For local audit, recording the actual administered dose and time, the exact ACT result and sampling time, and each subsequent dose would help separate an inadequate initial response from later maintenance requirements. This is an interpretation of the study’s documentation gaps, not an intervention tested by the investigators. The study did not compare antithrombin replacement, alternative anticoagulants, or competing dosing algorithms.
Limitations and Disclosures
Selection of only 30.0% of operations, non-random record availability, and underrepresentation of emergency and aortic surgery limit generalizability. The initial dose was reconstructed from body weight and the protocol rather than retained as an independently abstracted administration variable. Handwritten charts, uncertain redosing timing, and corrected laboratory transcription errors introduce additional uncertainty.
Antithrombin activity and anti-Xa measurements were unavailable, preventing assessment of mechanisms or comparison with heparin concentration. The primary outcome relied on one ACT measurement. Several sensitivity analyses were post hoc, and no external validation was performed. These findings apply to this dose, assay, sampling method, and patient mix.
The authors report no external funding and no conflicts of interest. They disclose AI assistance with analysis-code preparation and manuscript drafting and editing, with author verification and review. This educational summary is independently written from the source paper.
Original Article
Aytünür CS, Ata F. Inadequate Heparin Responsiveness Before Cardiopulmonary Bypass: Definition-Dependent Frequency and Limited Discrimination by Routine Preoperative Laboratory Values. Medicina. 2026;62(11):2286. doi:10.3390/medicina62112286.
The source PDF is unchanged. The cover is an AI-generated editorial illustration.